CORRECTING EQUIPMENT

  • Heating system
  • Co2
  • Ventilation
  • Screens


  • HEATING SYSTEM

    Influences
  • Heat
  • Air humidity
  • Water vapour
  • Plantcondition



  • Heating pipes
  • Radiation: direct to the plants
  • Convection: airheating

    Convection:
    Heating greenhouseuse
    Air circulation
    Removes moisture
    Result: Better climate and less diseases.

    Isıtma Boruları
    Dikey borular
  • Control of condensation at the top of the crop (cold clear nights)
  • Prevent cold temperature shock after opening thermal screens
  • Less condensation at the glass: more light



  • Co2

    Co2 and Heat storage tanks
  • CO2 during the day
  • Hot water during the night


  • VENTILATION


  • Both sides of the ridge
  • Control computer leeside and windside
  • Measuring position 0% to 100% and adjust if necessary
  • Seperate motors for both sides


  • Vents influences
  • Temperature
  • Air humidity
  • Co2 concentration


  • Vent design (size) dependant of
  • Climate
  • Growing season
  • Crop
  • Insects


    SCREENS

  • Energysaving up to 40%
  • Shading
  • Blocking of artificial light
  • Improve greenhouse climate

  • Different clothes

    Different properties
  • Lighttransmission
  • Insulation
  • Permeability to moisture
  • Blocking of artificial light


  • Glue-ing alu strips: higher insulation
    Open weave
    Low (15-20%)
    High
    Closer weave
    High (40%)
    Low

    Closing screen very important
  • Good closing: little air exchange with compartment above the screen
  • Not wel closing: cold air shock. It gives condensation on the plants
  • Constant opening to get rid of humidity

  • (Merkez Ofis) Zümrütova Mah. Sinanoğlu Cad. M.Günal Apt. 67/5 ANTALYA - Telefon:+90542 2310904 Faks:+90242 3246945 E-posta: info@troser.com